Product Center
137-8892-1527
AGV charging module power supply
AGV charging module power supply
PRODUCT DETAILS
4000W charging module power supply
Model: G1562-4000W
G1562 is a high-efficiency, high-power density digital rectification module with an input voltage range of 90-264Vac and a rated output voltage of 65Vdc, with PFC active power factor correction. This module is digitally controlled and communicates through CAN and 485 buses. Equipped with input overvoltage and undervoltage protection, output overcurrent and overvoltage
Voltage and short circuit protection.
Model |
Rated output voltage(Vdc) |
Current range (A) |
Output voltage regulating range(Vdc) |
Ripple (peak to peak)
|
G1562 |
65 |
0~61.5 |
55-80 |
350mV |
Input characteristics |
|||
Project |
Technical requirement |
Unit |
Remarks |
AC input voltage range |
90~264 |
Vac |
185Vac~264Vac output full load
|
Rated input voltage range |
185~264 |
||
Rated input voltage |
230 |
||
AC input voltage frequency |
44~66(额定值为 50/60) |
Hz |
|
Power factor |
≥0.99 |
|
Rated input, 100% load |
≥0.98 |
|
Rated input,50% load |
|
≥0.97 |
|
Rated input,30% load |
|
Total harmonic of input current |
5% |
|
Rated input,100% load |
8% |
|
Rated input,50% load |
|
12% |
|
Rated input,30% load |
|
Maximum input current |
≤25 |
A |
215Vac, fully loaded |
Inrush current |
≤30 |
A |
264Vac, cold state |
Output characteristic |
|||
Project |
Technical requirement |
Unit |
Remarks |
Output voltage regulating range |
55-80 |
Vdc |
Adjustable monitoring |
Rated output voltage |
65 |
Vdc |
|
Output current |
0-61.5 |
A |
Constant power 4000W above 65V, 55V~65V
|
Peak Efficiency |
≥95% |
|
230Vac、50% load |
≥94% |
|
230Vac、100% load |
|
Temperature coefficient |
±0.02 |
%/℃ |
|
Output ripple and noise |
≤350 |
mVp-p |
Input 230Vac, output 62Vdc~
|
Boot time |
3~10 |
S |
|
Output rise time |
≤200 |
mS |
The output voltage increases from 10% to 90% at rated load. |
On/off overshoot amplitude |
≤±5 |
%Vo |
Rated input voltage, output full load. |
Voltage stabilization accuracy |
≤±0.6%*Vo |
V |
|
Voltage setting accuracy |
≤±0.2 |
V |
Full output voltage range |
Current setting accuracy |
≤±0.5 |
A |
0-61.6 |
Project |
Technical requirements |
Unit |
Remarks |
Input undervoltage alarm point |
90 |
Vac |
Alarm function, no other processing required |
Input undervoltage protection point |
80±2 |
Vac |
|
Input undervoltage recovery point |
85±2 |
Vac |
Input voltage range
|
Input overvoltage protection point |
290±2 |
Vac |
|
Input overvoltage protection recovery point |
280±2 |
Vac |
|
Input frequency protection |
<44 or>66 |
Hz |
Turn off the output, return the input frequency to the normal range, and the output will automatically recover. |
Output overvoltage protection |
≥83 |
Vdc |
Locked, can only be restored after power outage and restart. |
Current limiting protection |
67±2 |
A |
Hiccup restart, automatic recovery after removal |
Short circuit protection |
Hiccup restart, automatic recovery after removal Hiccup restart, automatic recovery after removal |
> Products
> Solution
Follow us